BNCHG - EPK 11C KIT PART A (RESIN)
- MSDS: BNCHG
- Manufacturer: HYSOL DIV THE DEXTER CORP
- Product Name: EPK 11C KIT PART A (RESIN)
- National Stock Number: 8040-01-004-1031
Product Identification
Product ID:EPK 11C KIT PART A (RESIN)
MSDS Date:10/25/1984
FSC:8040
NIIN:01-004-1031
Kit Part:Y
MSDS Number: BNCHG
Responsible Party
OLEAN, NY 14760
US
Emergency Phone: 716-372-6300
Info Phone: 716-372-6300
Preparer: JAMES P HORNBURG
Cage: 14347
Contractor
Telephone: 716-372-6300/6309
Cage: 14347
Ingredients
CARBON BLACK
CAS: 1333-86-4
RTECS: FF5800000
Fraction By Weight: 1%
OSHA PEL NOT ESTABLISHED *
TALC
CAS: 14807-96-6
RTECS: WW2710000
Fraction By Weight: 45%
OSHA PEL NOT ESTABLISHED *
* FILLER PARTICLES ARE THOROUGHLY WETTED BY EPOXY RESIN SO
RTECS: 9999999ZZ
** SUBSEQUENTLY GROUND, MACHINED, OR SANDED.
RTECS: 9999999ZZ
Hazards
Health Hazards Acute and Chronic:MAY BE MILDLY IRRITATING TO THE SKIN.
First Aid
First Aid:WASH WITH SOAP AND WATER AT FIRST OPPORTUNITY.
Fire Fighting
Flash Point Method:COC
Flash Point:470F,243C
Extinguishing Media:CO2, FOAM, OR DRY CHEMICAL
Fire Fighting Procedures:NONE
Unusual Fire/Explosion Hazard:NONE
Accidental Release
Spill Release Procedures:SCRAPE UP, TRANSFER TO METAL CONTAINERS.
SOLVENT MAY BE NECESSARY TO CLEAN UP STICKY RESIDUE, BUT OBSERVE
FIRE HAZARD OF SOLVENT.
Handling
Handling and Storage Precautions:STORE AWAY FROM DIRECT HEAT, WHICH
MIGHT CAUSE PHYSICAL SEPARATION OF THE FILLER.
Exposure Controls
Respiratory Protection:NOT REQUIRED.
Ventilation:LOCAL EXHAUST: ONLY IF HEATED.
Protective Gloves:RUBBER OR PLASTIC.
Supplemental Safety and Health
Chemical Properties
Vapor Pres:NIL
Spec Gravity:1.5 (WATER=1)
Evaporation Rate & Reference:>1 (BU AC=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:BLACK, HIGH VISCOSITY LIQUID, VERY SLIGHT ODOR.
Percent Volatiles by Volume:0
Stability
Stability Indicator/Materials to Avoid:YES
Disposal
Waste Disposal Methods:NEW YORK STATE DOES NOT PERMIT LANDFILL BURIAL
OF LIQUIDS. SOLIDIFY BY MIXING WITH A PORTION OF PART B (HARDENER).
THIS IS NOT A HAZARDOUS MATERIAL UNDER THE RESOURCE CONSERVATION
AND RECOVERY ACT (RC RA).
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.